Make a contributionIf the overall deployment STATUS is Error, rapyuta.io displays an error code along with a brief description of the error. Listed below are the error codes and the recommended actions to resolve them:
Error code | Description | Recommended action |
---|---|---|
DEP_E151 | Device is either offline or not reachable | Ensure that the device is connected to the internet. |
DEP_E152 | Executables of the component deployed on the device either exited too early or failed | In the docker deployments this may indicate an error with the entry point or command, verify and fix it. |
DEP_E153 | Unable to either pull the docker image or build the source code for the component deployed on cloud | Ensure that the docker image provided while adding the package still exists at the specified registry endpoint. |
DEP_E154 | Executables of the component deployed on cloud exited too early | Troubleshoot the failed component by analyzing the deployment logs. |
DEP_E155 | Executables of the component deployed on cloud failed | Troubleshoot the failed component by analyzing the deployment logs |
DEP_E156 | Dependent deployment is in error state | Troubleshoot the dependent deployment that is in error state |
DEP_E161 | Docker image not found for executables of components deployed on device | Ensure that the docker image path is valid. |
DEP_E162 | Validation error. Cases include:
|
|
DEP_E163 | Application has stopped and exited unexpectedly, and crashes continuously | Debug the application using the corresponding deployment logs. |
DEP_E171 | Cloud bridge encountered duplicate alias on the device | Change the alias name during deployment and ensure that there is no duplication of alias name under the same routed network. |
DEP_E172 | Compression library required for the cloud bridge is missing on the device | Re-onboard the device. |
DEP_E173 | Transport libraries required for the cloud bridge are missing on the device | Re-onboard the device. |
DEP_E174 | Cloud bridge on the device encountered multiple ROS service origins | Ensure that there aren’t multiple deployments with the same ROS service endpoint under the same routed network. |
DEP_E175 | Python actionlib/msgs required for the cloud bridge is missing on the device. | Re-onboard the device. |
DEP_E176 | Cloud bridge encountered duplicate alias on the cloud component | Change the alias name during deployment and ensure that there is no duplication of alias name under the same routed network. |
DEP_E177 | Cloud bridge on the cloud component encountered multiple ROS service origins | Re-onboard the device. |
DEP_317 | Failed to start |
|
DEP_E2xx | Internal rapyuta.io error in the components deployed on cloud | Report the issue together with the relevant details to the support team |
DEP_E3xx | Internal rapyuta.io error in the components deployed on a device | Report the issue together with the relevant details to the support team |
DEP_E4xx | Internal rapyuta.io error | Report the issue together with the relevant details to the support team |